Home » Stare » OctState
temperatura   umiditate   presiune   presiune rapid variabila   presiune diferentiala   viteza vantului   impulsuri   eveniment   stare   soc   vibratie / trepidatie  
 

 

 

OctState - Inregistrator de Stare cu 8 canale

OctState

Dimensiuni:    89 mm x 112 mm x 39 mm

Categoria:   Uz General

Applications

  • Security Systems
  • Power On/Off
  • Time Studies
  • Status or State Recording

Pret  - la cerere

Marca:   MadgeTech

Tara de fabricatie:   SUA

OctState masoara
si inregistreaza:

  • starea



Features

  • Real-Time Operation
  • Accepts TTL or Contact Closure Inputs
  • Compact
  • Programmable Engineering Units
  • Programmable Start Time

 

The QuadState and OctState offer all the performance of the State101 with the addition of a four channel or eight channel capacity.

State loggers are useful for collecting data on the duration of an event. Our loggers can capture any event that lasts longer than one second. Some typical applications for state loggers include monitoring a furnace, air conditioner or pump turning on and off or how long a door is left opened or closed.

Our state loggers record a time-stamped value whenever the state of the input signal changes. They sample the state of the input at a user specified time interval and record to memory only if the state has changed from the previous sample. This efficient method of writing to memory maximizes the length of time the data loggers can record.

The QuadState and OctState data loggers are multiple channel state loggers which can each record up to 52,428 time stamped state changes. The QuadState is a four channel logger, while the OctState has eight input channels.

The MadgeTech state loggers and software have the unique ability to allow user-chosen Engineering Units to be entered into the loggers. This allows for complete flexibility for each application. For example, a water pump, when on, pumps 10 liters / minute. Using the Engineering Units in software, the state logger can set up to equate the ON state with 10 liters and the OFF state with 0 liters. After the data is offloaded, the units displayed will be in units of liters (instead of "1" or "0") and the summary will show, for example, the average volume of water pumped.

If a custom analysis of state data is necessary (even in Engineering Units), one click will bring the data into an MS Excel® spreadsheet.

 

Specifications

   

OctState

Input Range:
 
0~12 VDC continuous; 0~30 VCD peak
Input Low:
 
<0.4V
Input High:
 
>2.7V
Internal Weak Pull-Up:
 
<500μA
Recommended Duty Cycle for Inputs Greater than 12VDC (over 1 minute interval):
 
18V:<50%, 24V:<25%, 30V:<10%
Resolution:
 
1 second
Channels:
 
8
Memory:
 
52,428 states
Sample Rate:
 
1 second up to 12 hours
LED Indicator:
 
None
Required Interface Package:
 
IFC110 or IFC200
Baud Rate:
 
2,400
Typical Battery Life:
 
1 year
Operating Environment:
 
-20~+60°C, 0~95%RH non-condensing
Material:
 
Anodized aluminum
Dimensions:
 
3.5" x 4.4" x 1.5" (89mm x 112mm x 39mm)
CE Approval:
 
No
Weight:
 
17oz.
Designed and manufactured in the USA. CE Conformity.

 

OctState Graph - MadgeTech Software

OctState Graph - MadgeTech Software

Analyze data using the software’s powerful tools to examine, export, and print professional-looking graphs.

 

Reminder !   IFC computer interface cable required for computer (PC) operation of data loggers. Check the accessories selection below.


Accesories / Software

Description

IFC110 Includes software, manual and RS232 computer interface cable
IFC200 Includes software, manual, Quick Start Guide and USB computer interface cable
Note: USB drivers are compatible with Vista 32 bit systems, not Vista 64 bit systems.
USB-1 USB to RS232 converter cable
USB101 Includes software, manual, RS232 (IFC110) computer interface cable and USB to RS232 converter cable
CT-800 Current switch, 1 A set point
CT-805 Current switch, 1.5 A set point
CT-815 Current switch, adjustable set point with split core and LED
CT-H600 Current relay switch, 0.15 - 200 A, fixed set point, no status LEDs
CT-H608 Current relay switch, 1.25 - 50 A, adjustable set point, status LEDs
U9VL-J 9.0 Volt, Lithium Battery, 1200 mAH



Cum platim ?

Pentru a afla modul de plata, luati legatura cu noi prin pagina Contact.

 

 

< Sus >

Copyright © Ascora 2009-2010 Toate drepturile rezervate